Menampilkan 1–16 dari 58 hasilDiurutkan menurut yang terbaru
- IEEE-61850-3, IEEE-1613
- Single Mode, SC Fiber
- -40 to 85°C Operating Temperature
- Rugged, IP30 Metal Panel Mount Case
- 50G Shock, 4G Vibration
- 2kV Triple Isolation
- Converts serial data signals to multi- or single-mode fiber
- 2 KV, 3-way isolation (input, output, power circuits)
- Data rate: 9.6 to 115.2 kbps (bit-wise enable)
- -40 to +85°C wide operating temperature
- IP30 metal panel mount case (DIN rail adaptable)
- FCC, CE, IEC-61850-3, IEEE 1613, UL C1/D2
- Note: 2 units required to extend data via fiber optic connection (see datasheet)
- 10-48 VDC power source required (not included, sold separately)
- Converts serial data signals to multi-mode fiber
- Inverted fiber state – fiber Off in idle state
- 2 KV, 2-way isolation; EMI/RFI protection
- Data rate: up to 115.2 kbps
- Wide operating temperature: -40 to +80 °C
- DIN rail mount
- 10-30 VDC power source required (not included, sold separately)
- Converts serial data signals to multi-mode ST fiber optic
- Inverted fiber state - fiber light OFF in idle state
- 2 KV 3-way optical isolation (input/output/power); EMI/RFI protection
- Data rate: up to 115.2 kbps
- Wide operating temperature: -40 to +80 °C
- DIN mount, IP20 plastic case
- 10–48 VDC power source required (not included, sold separately)
- UL Class 1 / Division 2 rated
- Three stages of protection on every data line: Gas discharge tube, Series resistor, Transient voltage suppressor
- Protected signal ground connection
- Rugged terminal block connections
- Dedicated chassis ground lug
- Wide operating Temperature
- NEMA TS2
- Boost signals and increase node capacity of CAN networks
- Works with various CAN protocols and frame lengths
- 2,000V optical isolation protection from surges and spikes
- Data rate: up to 250 kbps (bit-wise enable)
- Terminal block CAN connections (copper)
- DIN rail mount enclosure - ideal for industrial cabinets
- 10-30 VDC external power required (not included, sold separately)
- Three stages of protection on every data line: 1) Gas discharge tube 2) Series resistor 3) Transient voltage suppressor
- Protected signal ground connection
- Rugged terminal block connections
- Dedicated chassis ground lug
- Protects RS-422 or RS-485 ports
- 600W serial circuit surge suppression
- 125 mA fast-acting PCB fuses
- Simple in-line installation
- One time use, disposable unit
- Three stages of protection on every data line: 1) Gas discharge tube 2) Series resistor 3) Transient voltage suppressor
- Protected signal ground connection
- Rugged terminal block connections
- Dedicated chassis ground lug
- Three stages of protection on every data line: 1)Gas discharge tube, 2)Series resistor, 3)Transient voltage suppressor
- Protected signal ground connection
- Five Postion Terminal Block
- Dedicated chassis ground lug
- 2.5 KV Isolation
- Data rates up to 115.2 kbps
- DB9 F / DB9 M
- Port-powered on both sides, no external powersupply required
- 2.5kV isolation
- 15kV ESD protection
- Data rate: 230.4 kbps
- Quick in-line installation
- 12 VDC Power supply required, sold separately